Generator Set Specifications

Maximum Rating

800 ekW

Minimum Rating

635 ekW

Emissions/Fuel Strategy

Low Fuel Consumption

Voltage

220 to 480 Volts

Frequency

60 Hz

Speed

1800 rpm

Duty Cycle

Standby, Prime

Engine Specifications

Engine Model

3412C TA, V-12, 4-Stroke Water-Cooled Diesel

Bore

5.4in

Stroke

6in

Displacement

1648.86in³

Compression Ratio

13:00:01

Aspiration

TA

Fuel System

Pump and Lines

Governor Type

ADEM™ A5

Generator Set Dimensions

Length - Maximum

162.4in

Width - Maximum

78.3in

Height - Maximum

75in

Dry Weight - Genset (minimum)

5761lb

Dry Weight - Genset (maximum)

13275lb

Standard Equipment:

  • Air Inlet System
    • Air cleaner, single element canister type
    • Single element canister type
  • Control Panel
    • Failure to start (overcrank)
    • Emergency stop
    • EMCP 4.2B
    • Speed adjust
    • Remote Serial annunciator
    • Communications:
    • Controls:
    • Digital Indicator for:
    • Engine cycle crank
    • Voltage adjust
    • Compatible with the following optional modules:
    • Digital I/O module
    • Overspeed
    • Low coolant level
    • Serial annunciator module data link
    • Volts (L-L & L-N)
    • Emergency stop pushbutton
    • Generator temperature monitoring module
    • Frequency (Hz)
    • Run/auto/ stop/control
    • DC volts
    • High coolant temperature
    • Oil pressure (psi, kPa or bar)
    • Customer data link (Modbus RTU)
    • RPM
    • coolant temperature
    • Amps (per phase & average)
    • Operating hours.
    • Local annunciator
    • Low oil pressure
    • Power factor (per phase & average)
    • Remote CAN annunciator
    • Low coolant temperature
    • Accessory module data link
    • Warning shutdowns:
  • Cooling System
    • Coolant drain line with valve
    • Caterpillar extended life coolant
    • Fan and belt guards
    • Radiator with guard (sized for 50 degrees C)
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange
  • Fuel System
    • Primary and Secondary fuel filters
    • Water separator
    • Fuel priming pump
  • Generator And Attachments
    • 3 Phase sensing
    • Class H insulation
    • Busbar termination
    • 12 Leads
    • SR4B self excited
    • Reactive droop
    • Class F temperature rise
    • VR6B voltage regulator
    • 2:1 Volts/Hz
  • Governing System
    • Cat electronic governor
  • Lube System
    • Oil drain line with valve
    • Oil filter
    • Lubricating oil
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 45 Amp Charging alternator
    • Fuel shutoff solenoid
    • 24 Volt starting motor
    • Battery with rack, cables
  • General
    • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment:

  • Air Inlet System
    • Air cleaner - single element
    • Air cleaner - Dual element
    • Air cleaner - Heavy element
  • Certificates
    • EU Certification
  • Circuit Breakers
    • 3 Pole Circuit breakers with shunt trip
    • Power terminal strip
    • 4 Pole Circuit breakerswith shunt trip
  • Control Panel
    • Temperature monitoring package
    • EMCP 4.3, EMCP 4.4
    • Vandal proof panel door
    • Common alarm/shutdown relay
    • Generator running VFC
    • Earth leakage Ground fault relay
  • Cooling System
    • Radiator removal
    • Jacket water heater
    • Radiator duct flange
  • Exhaust System
    • Through wall installation kit
    • Manifold and turbocharger guards
    • Muffler 35 dBA attenuation
    • Muffler 10 dBA attenuation
    • Elbow mounting kit
  • Fuel System
    • Automatic fuel transfer system
    • Manual fuel transfer pump
  • Generator And Attachments
    • Oversize and premium generators
    • Permanent magnet excitation (PMG)
    • Anti-condensation heater
    • Internal excitation (IE)
  • Governing System
    • Electronic load share
  • Lube System
    • Manual sump pump
  • Mounting System
    • Fuel tank base (1200 Ltr)
  • Special Tests / Reports
    • PGS Test report @ 1.0 power factor
    • Factory witness test
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • Battery chargers
    • Oversize battery set
    • Heavy duty starting system
    • Battery disconnect switch
    • Battery removal
  • Enclosures
    • DC lighting package
    • Weather protective enclosure (WP)
    • Sound attenuated enclosure (SA)