Black banner

C4.4 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Maximum Rating

60 ekW

Minimum Rating

36 ekW

Emissions/Fuel Strategy

U.S. EPA Cert., Tier 3

Voltage

208 to 600 Volts

Frequency

60 Hz

Speed

1800 rpm

Duty Cycle

Standby, Prime

Engine Specifications

Engine Model

C4.4, In-line 4, 4-cycle diesel

Bore

4.13in

Stroke

5in

Displacement

268.5in

Compression Ratio

18.2:1

Aspiration

Turbocharged

Fuel System

Electronic (adjustable)

Governor Type

Adem™A4

Generator Set Dimensions

Length - Maximum

75.8in

Width - Maximum

44.1in

Height - Maximum

53.6in

Standard Equipment:

  • Certificates
    • IBC seismic and wind Certifications
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Air Inlet System
    • Air cleaner
    • Cartridge type air filter
  • Circuit Breakers
    • Second circuit breaker box
    • 3-Pole 100% rated
    • Power terminal strip
    • Breakers (100% UL rated)
  • Control Panel
    • 1000028996
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator stone guard
  • Generator
    • 12 Leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Oil drain line with valve
    • Lubricating oil
  • Control Panels
    • WCA1 Low coolant temperature alarm
    • WSS1 Low coolant level shut down
    • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • NFPA110 bundle includes:
    • PAA1 Panel mounted audible alarm
    • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature gauge and sender
    • PBC10NU NFPA battery charger
    • Ground fault relay
    • Discrete I/O module
    • Volt free contacts genset run and common alarm
    • Audible alarm
    • Remote E-stop button
    • Remote annunciator module
    • Low coolant temperature alarm
    • Protective devices:
    • Overload shutdown via breaker
    • Fuel level reading
    • Low coolant level shutdown
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Starting/charging System
    • 24V battery with rack and cables
    • Batteries

Optional Equipment:

  • Certificates
    • IBC seismic and wind Certifications
  • Alternator System
    • R Frame auxilliary winding
  • Air Inlet System
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • 3-Pole 100% rated
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • Power terminal strip
  • Control Panels
    • Discrete I/O module
    • Remote annunciator module
    • Remote E-stop button
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Ground fault relay
    • Audible alarm
    • Oil temperature gauge and sender
    • Volt free contacts genset run and common alarm
    • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
  • Heating Elements
    • Coolant heater
    • Battery heater
    • Anti-condensation heater
    • Lube oil sump heater
    • Jacket water heater
    • Wiring for canopy space heater
  • Cooling System
    • Radiator transition flange
  • Enclosures
    • Panel viewing window
    • External emergency stop
    • Sound attenuated enclosure, Level 2
    • Weatherproof enclosure
    • Sound attenuated enclosure, Level 1
  • Fuel System
    • 5 Gallon fill containment
    • Tank riser
    • 209 and 394 gallon sub-base fuel tanks
    • Emergency vent pipe
    • 5 Gallon spill containment
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • Generator test report
    • PGS Test report @ 0.8 power factor
    • 4 Hour factory test
    • PGS Test report @ 1.0 power factor
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
  • Generators
    • Permanent magnet excitation (PMG) generator

Contact Us

Get A Quote

Thank you for your interest in Mustang Cat. We are here to help you in any way that we can. If you have a question, need equipment advice or just need additional information, we want to hear from you. You can email, phone or fill out the form below and we will be happy to connect with you.

    true I agree to all the terms and conditions

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.