3516B Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Prime Power Rating

1825 ekW

Continuous Rating

1640 ekW

Emissions/Fuel Strategy

Low Fuel Consumption

Voltage

380 to 13800 Volts

Frequency

60 Hz

Speed

1800 rpm

Duty Cycle

Prime, Continuous

Maximum Rating

1825 ekW

Minimum Rating

1640 ekW

Engine Specifications

Engine Model

3516B TA, V-16, 4-Stroke Water-Cooled Diesel

Bore

6.69in

Stroke

7.48in

Displacement

4210.64in

Compression Ratio

14.0:1

Aspiration

TA

Fuel System

Electronic unit injection

Governor Type

Adem™4

Generator Set Dimensions

Length - Maximum

258.1in

Width - Maximum

90.1in

Height - Maximum

94.1in

Dry Weight - Genset (maximum)

33300lb

Standard Equipment:

  • Air Inlet System
    • Air cleaner, single element canister type
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Primary fuel filter with integral water separator
    • Secondary fuel filters
  • Control System
    • Generator set packages include Caterpillars voltage regulator
    • 6 Customer programmable digital inputs
    • Controls:
    • Low coolant temperature
    • Auto/start/stop control
    • Low coolant level
    • Customer data link (Modbus RTU)
    • PLC functionality
    • kVA (per phase, average & percent)
    • Reverse power (kW) (32)
    • Alarm acknowledge
    • kW (per phase, average & percent)
    • kW-hr (total)
    • Lamp test
    • RPM
    • Volts (L-L & L-N), frequency (Hz)
    • Generator phase sequence
    • Operating hours
    • kVAr-hr (total)
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Over/under frequency (81 o/u)
    • Accessory module data link
    • Number of I/O varies on options selected
    • High coolant temperature
    • Overspeed
    • 1 Programmable digital outputs
    • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
    • DC volts
    • Reverse reactive power (kVAr) (32RV)
    • Amps (per phase & average)
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Failure to start (overcrank)
    • 3 Analog inputs
    • Power factor (per phase & average)
    • EMCP 4.3
    • kVAr (per phase, average & percent)
    • Cat connect
    • Engine cool-down timer
    • 1 Programmable relay outputs (Form C)
    • Environmental sealed front face
    • Warning/shutdown with common LED indication of shutdowns for:
    • 24 Volt DC operation
    • Over/under voltage (27/59)
    • Emergency stop pushbutton
    • Limiter and exciter diode monitor
    • Generator mounted - rear facing
    • Digital indication for:
    • Text alarm/event descriptions
    • Customizable screens
    • Load histogram feature
    • Emergency stop
    • Serial annunciator module data link
    • Programmable protective relaying functions:
    • Low oil pressure
    • Communications:
    • Speed adjust
    • Engine cycle crank
    • 4 Programmable relay outputs (Form A)
    • Overcurrent (50/51)
  • Power Termination
    • Busbar
  • Control Panel
    • Cat ECS Genset controller
  • Cooling System
    • Package mounted radiator
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Secondary fuel filters
    • Fuel priming pump
  • General
    • SAE standard rotation
    • Flywheel and Flywheel housing-SAE No. 00
    • Paint - Caterpillar yellow except rails and radiators gloss black
    • RH service
  • Generators And Attachments
    • Matched to the performance and output characteristics of Cat engines
    • Random wound
    • IP23 Protection
    • Anti-condensation space heater
    • 3 Phase brushless, Salient pole
    • HV:
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
    • LV
    • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
    • 6 Lead
    • Form wound
    • Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
    • Winding temperature detectors
    • MV:
    • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Governing System
    • ADEM A3
  • Lube System
    • Oil drain lines and valve
    • Lubricating oil
    • Integral lube Oil cooler
    • Oil filter, filler and dipstick
    • Fumes disposal
    • Gear type lube oil pump
  • Mounting System
    • Rails - Engine/generator/radiator mounting.
    • Rubber anti-vibration mounts - shipped loose
    • Anti-vibration mounts (shipped loose)
  • Starting System
    • Battery disconnect switch
    • 24 Volt electric starting motor
    • 45 Amp Charging alternator
    • Battery and battery rack w/cables

Optional Equipment:

  • Exhaust
    • Exhaust mufflers
  • Air Inlet System
    • Standard ambient radiators
    • Dual element air cleaner
    • Standard ambient ATAAC radiators
    • Single element filter
    • Optional radiator arrangements
  • Generator
    • Anti-condensation heater
    • Permanent magnet excitation (PMG)
    • Oversize and premium generators
    • Internal excitation (IE)
  • Control Panels
    • EMCP 4.4
    • Load share module
    • Digital I/O module
    • Generator main terminal box
    • Remote monitoring software
    • Vandal proof panel cover
    • Generator temperature monitoring & protection
    • Empty upper box
    • Cable Shroud
    • Annunciator - local
    • Digital I/O module
    • Annunciator - remote
    • Side extension box
  • Cooling System
    • Coolant
    • Water level switch gauges
  • Crankcase Systems
    • No explosion relief valves
    • Explosion relief valves
    • Crankcase ventilation systems
    • Crankcase protection groups:
  • Mounting
    • Rubber anti-vibration mounts
    • IBC isolators
  • Exhaust System
    • Flange and exhaust expanders
    • Flexible fittings
    • Tier 4 lean emissions moDual
    • Flanges
    • Elean emission parts
    • Tier 4 dosing cabinet
    • Exhaust offset
    • Mufflers
    • Tier 4 clean emission MOD kits
    • Y Adapters
    • Elbows>
  • Starting/charging
    • Oversize batteries
    • Charging alternator
    • Heavy duty starting system
    • Jacket water heater
    • Battery chargers
  • General
    • CSA Certification
    • EEC Declaration of Conformity
    • Automatic transfer switches (ATS)
    • UL 2200 package
    • Integral & sub-base UL listed dual wall fuel tanks
    • EU Certificate of Conformance (CE)
    • Integral & sub-base fuel tanks
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Enclosures: Sound attenuated, weather protective
    • The following options are based on regional and product configuration:
  • Extended Service Coverage
    • Platinum, Silver and Gold coverage
  • Fuel System
    • Primary fuel filter
    • Fuel priming pumps (Tier 4)
    • Gas fuel filter
  • Generators And Attachments
    • Generator conversions
    • Hi voltage optional attachments
    • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
    • Generators high voltage
    • Differential current transformers
    • 1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
    • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
    • Alternator air cleaner
    • 1800 Frame
    • Space heater kit
    • 3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
  • Instrumentation
    • Pyrometer and termocouples
  • Lube System
    • Oil level regulator
    • Prelube pump groups
    • Lube oil in standard sump
  • Mounting System
    • IBC vibration isolators
    • Puck style low efficiency isolators
    • Spring type vibration isolators
  • Power Connections
    • Center post busbars
    • Cable entry - rear
    • Rear power connections
    • Cable entry - right side
    • Cable entry - left side
    • Grounding groups
    • Neutral ground connections
    • Right side power connections
    • left side power connections
  • Power Termination
    • Circuit breakers - LV Packages
    • 2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
    • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
    • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
  • Special Tests / Reports
    • Generator set report
    • PGS Test report @ 0.8 power factor
    • Fuel consumption test
    • Torsional vibration analysis
    • Seismic Certifications
    • PGS Test report @ 1.0 power factor
    • Standard engine test
    • OSPD Certification
  • Starting / Charging
    • 10, 20, 35 Amp Battery chargers
    • Engine barring device
    • Batteries, racks and cables
    • Jacket water heaters
    • Air starting motors with control and silencer
    • Electric starting motors
    • Starter cover
    • 50 Amp NFPA battery charger
    • Air pressure regulator

Contact Us

Get A Quote

Thank you for your interest in Mustang Cat. We are here to help you in any way that we can. If you have a question, need equipment advice or just need additional information, we want to hear from you. You can email, phone or fill out the form below and we will be happy to connect with you.

    true I agree to all the terms and conditions

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.